Skip to product information
1 of 8

SKU:1090

4 Channel TENS EMS machine STIM-PRO X9B with rechargeable battery and soft case

4 Channel TENS EMS machine STIM-PRO X9B with rechargeable battery and soft case

Regular price €199,95
Regular price €0,00 Sale price €199,95
Sale Sold out
Taxes included. Shipping calculated at checkout.
  • Medical device certified according to MDR (EU) 2017/745
  • Personal support from medical device consultants
  • Developed in Germany
  • 3-year warranty - Exclusively when ordering in the online shop

Free exclusively when purchasing on www.axion.shop

- Electrodes (round), Ø 3.2 cm - 4 pieces

- free warranty extension to a total of 3 years

Free and fast shipping

The resulting delivery costs will be calculated in the shopping cart.

The shipping conditions for countries outside of Germany can be found on our shipping page

Note: Electrodes are hygiene items and are therefore non-returnable after the seal has been removed. For more information, see the on our returns page .

Return

You can return the device to us within 30 days . Our terms and conditions apply.

Scope of delivery

  • STIM-PRO X9B
  • 8 Electrodes (5x5 cm)
  • 4 Electrodes (10x5 cm)
  • 4 Round Electrodes (⌀ 3.2 mm)
  • 4 Connection cables
  • 1 USB charger
  • 1 Handy soft case
  • 1 User manual
  • 1 Brochure: "Suggestions for Electrode Placement"

Manufacturer

axion GmbH

Mollenbachstr. 13

71229 Leonberg

service@axion.shop

Safety Instructions

The stimulation emitted by the device may be sufficient to cause an electric shock. Electric current of this magnitude must not flow through the rib cage (thorax) or through the chest and the upper back, as it can cause cardiac arrhythmia. Do not place electrodes over the heart!

Do not place electrodes on the front of the throat as spasm of the laryngeal and pharyngeal muscles may occur. Stimulation over the cervical cavity (throat area) may close the airway, make breathing difficult, and have negative effects on the heart rhythm or blood pressure.

Do not place electrodes on your head or in places where the electric current can flow transcerebrally (through the head).

If the therapy is ineffective or becomes uncomfortable, stimulation should be discontinued until its use is re-evaluated by a physician.

The device does not have AP/APG protection. Do not use it in an explosive atmosphere or close to flammable mixtures.

The device may only be used according to medical advice.

Electrodes must not be placed over the eyes, the mouth or inside the body.

The device is to be used only when awake.

Do not use the device near other electrical equipment or power sources.

If you experience pain, skin irritation, dizziness, difficulty breathing or other unusual symptoms while using the device, discontinue use and consult a physician immediately.

Use only original accessories from the manufacturer with your device (see scope of delivery).

Do not use this device for undiagnosed pain symptoms before consulting a physician.

Do not use this device while driving, operating machinery, near water, or during activities where involuntary muscle contractions may expose the user to excessive risk of injury.

Always turn off the unit before applying to or removing accessories from the skin or mucosa.

Keep this device out of the reach of children.

The device has no curative effect.

Electronic monitoring devices (such as ECG monitors and ECG alarms) may not function properly when electrical stimulation is used.

The device should be cleaned with soapy water on a clean cloth after each use.

The device is an electronic product and must therefore not be disposed of with residual waste. Further information at: https://axion.shop/en/pages/environment-and-disposal

For first-time users, muscle stimulation can be an unfamiliar sensation. It is recommended to start at a low intensity in a sitting position to familiarize yourself with the feeling before increasing the intensity.

Consult a physician before using the device after giving birth.

If an IUD is employed for contraception, consult a physician before use of the device.

Please wait until your menstrual period is over, because during this time heavy use of the abdominal muscles is not recommended.

If the battery fluid leaks and has come into contact with the skin, rinse the affected area thoroughly with plenty of clean water.

If the battery fluid comes in contact with your eyes, avoid rubbing your eyes. Flush your eyes thoroughly with plenty of water and seek medical attention immediately.

If you notice unusual heat, odors, or flames coming from the battery, stop using the device.

Simultaneous connection of a patient to a high frequency surgical equipment and the stimulator may result in burns at the site of the stimulator electrodes and possible damage to the stimulator.

Do not operate the product within 1 m of shortwave or microwave therapy equipment as it may produce instability in the stimulator output.

View full details

We have created a page with detailed videos covering the basic functions and settings of the STIM-PRO X9B.

Modern pain therapy and muscle stimulation that‘s suitable for the highest demands. The new 4 channel TENS-EMS machine the STIM-PROX9B

Discover the new, significantly improved successor to the STIM-PRO X9+ - a device that has been considered one of the leading TENS-EMS devices on the market for many years. Benefit from the latest technology and optimised programmes for better therapy results.

  • 4 separately adjustable channels

    For the use of up to 8 electrodes simultaneously

  • 99 intensity levels

    For a comfortable application that is specific to your needs

  • Rechargeable lithium-ion battery

    The powerful battery can be easily charged with a standard USB-C cable

  • 60 programmes

    Of these, 57 pre-installed TENS, EMS and massage programmes, which are a further improvement on the previous device

  • Freely adjustable parameters

    3 therapy modes (Normal TENS, Burst TENS and EMS), which can be customised by you or your doctor

  • Use 2 programmes simultaneously

    This makes it possible to treat two different areas of the body or two people at the same time .

Genuine 4-channel device - Despite the 2 programmes, the intensity of all 4 channels remain separately controllable

  • Non-pharmacological pain therapy

  • Joint-friendly and time-saving muscle training

  • Gentle, relaxing electrical stimulation massage

  • Pelvic floor training against incontinence

1 of 4

For beginners and professionals

60 programmes including TENS and EMS therapy mode

Due to lessons learned from many years of experience in the field of TENS machines, the X9B has a variety of pre-installed programmes for the most common types of pain , so that you can easily start immediately without much experience.

For experienced users and medical professionals, there are therapy
modes (Normal TENS, Burst TENS and EMS)
. These can also be used to set up
your own programmes using freely selectable parameters.

Improved display and battery operation

Highest technical standard

Our TENS machine has all the technical features that patients want for electrotherapy.

In addition to a powerful battery that is charged using a standard USB-C, the X9B also has a backlit display that is easy to read from any angle.

We are here for you

High security and competent support

As a manufacturer, we attach great importance to offering you a user experience that meets the highest standards of comfort, safety and user-friendliness. Our devices are all medically certified. Should you have any questions or problems, our qualified medical device consultants are always happy to help.

  • Neck pain

    Electrode placement, programme selection of the axion TENS machines and causes of neck pain

    To the application page 
  • Shoulder pain

    Electrode placement, programme selection of the axion TENS machines and causes of shoulder pain

    To the application page 
  • Knee pain

    Electrode placement, programme selection of the axion TENS machines and causes of knee pain

    To the application page 
  • Heel pain

    Electrode placement, programme selection of the axion TENS machines and causes of heel pain

    To the application page 
  • Polyneuropathy

    Electrode placement, programme selection of the axion TENS machines and causes of polyneuropathy

    To the application page 
  • Lower back pain

    Electrode placement, programme selection of the axion TENS machines and causes of back pain

    To the application page 
  • Sciatica pain

    Electrode placement, programme selection of the axion TENS machines and causes of sciatica pain

    To the application page 
  • Tennis elbow

    Electrode placement, programme selection of the axion TENS machines and causes of tennis elbow

    To the application page 
1 of 8

Please note: The information on axion.shop does not constitute medical advice. If you have any questions or problems relating to electrical stimulation therapy, please contact our certified medical product advisors or consult your doctor .

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)